CO₂ emitted3.92Mt2023 · reported to EPA · 108th highest of 6,030 in the US
Rank in Florida#22of 310 · by capacity · #206 of 13,147 US
Reported suppliers32023 · 46 deliveries
Capacity factor48%2023
Location
What it burns
2023 · reported
Share of reported fuel consumption
60% Coal · 31 TBtu · reported · $117M est.40% Natural gas · 20.8 TBtu · reported · $77.5M est.
Coal supplies 60% of the fuel energy it burned in 2023.
CO₂ emitted, Mt · 2011–2023
Reported (through 2023)
Generating units
4 of 4 shown · 1,262 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit 1
464.5
Bituminous coal
Conventional Steam Coal
1987
Operating
Unit 2
464.5
Bituminous coal
Conventional Steam Coal
1996
Operating
Unit B1
203.2
Natural Gas
Natural Gas Fired Combined Cycle
2010
Operating
Unit B
129.8
Natural Gas
Natural Gas Fired Combined Cycle
2010
Operating
All 4 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; co-firing fuels and fuel-switching times; SO₂ scrubber type, sorbent and removal efficiency; NOₓ, particulate and mercury controls with compliance years; cooling system and water source with withdrawal rate; stack height; ownership stakes where a unit is jointly held.
Figures are volumes delivered in 2023, not volumes burned. Tons are shown for coal only.
Showing 1 of 3 suppliers. Subscribe to see all 3, every one of the 861 deliveries recorded 2011–2023, mine-level origins, transport mode and the delivered price paid — plus sorting, filtering and Excel export.
1,262 MW across 4 generating units in service — 929 MW of coal and 333 MW of natural gas.
Who owns and operates it?
Owned by Orlando Utilities Commission (inc) and operated by Orlando Utilities Comm, filed as municipally owned utility. 3 owner stakes are filed on jointly held units.
Which grid does it sell into?
FMPP (Florida Municipal Power Pool) is its balancing authority, inside NERC's SERC region.
How old is it?
The capacity-weighted average megawatt here came online in 1996. The oldest operating unit is Unit 1 (1987); the newest are Unit B1 and Unit B (2010).
When is it due to retire?
No retirement date has been filed for any operating unit at Curtis H. Stanton Energy Center. An absent date means none is currently filed, not that the plant will run indefinitely.
What does it burn, and where does the fuel come from?
In 2023 it burned coal and natural gas. Coal delivered in 2023 came from 2 coal suppliers, from mines in Indiana and Illinois — principally Oaktown Fuels Mine #1. Other fuels (natural gas) came from 1 supplier in 2023.
How much does it spend on fuel?
An estimated $194M in 2023 — coal $117M and natural gas $77.5M. No agency publishes this site's whole fuel bill, so this is an AEA estimate rather than a reported figure.
How much CO₂ does it emit?
3.92 Mt in 2023, reported to the EPA — the 108th highest of 6,030 US facilities that reported. Down from 4.84 Mt in 2011.