CO₂ emitted3.03Mt2023 · reported to EPA · 158th highest of 6,030 in the US
Rank in Wisconsin#6of 258 · by capacity · #328 of 13,147 US
Reported suppliers42023 · 56 deliveries
Capacity factor41%2023
Location
What it burns
2023 · reported
Share of reported fuel consumption
99% Coal · 32.9 TBtu · reported · $81.1M est.1% Natural gas · 0.166 TBtu · reported · $566,713 est.
Coal supplies 99% of the fuel energy it burned in 2023.
CO₂ emitted, Mt · 2011–2023
Reported (through 2023)
Generating units
6 of 6 shown · 946 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit 4
595.0
Subbituminous
Conventional Steam Coal
2008
Operating
Unit 3
350.5
Subbituminous
Conventional Steam Coal
1981
Operating
Unit 2
81.6
Natural Gas
Natural Gas Steam Turbine
1960
Retired 2023
Unit 1
60.0
Subbituminous
Conventional Steam Coal
1954
Retired 2015
Unit 32
56.7
Natural Gas
Natural Gas Fired Combustion Turbine
1973
Retired 2023
Unit 31
19.6
Natural Gas
Natural Gas Fired Combustion Turbine
1969
Retired 2023
All 6 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; co-firing fuels and fuel-switching times; SO₂ scrubber type, sorbent and removal efficiency; NOₓ, particulate and mercury controls with compliance years; cooling system and water source with withdrawal rate; stack height; ownership stakes where a unit is jointly held.
Figures are volumes delivered in 2023, not volumes burned. Tons are shown for coal only.
Showing 1 of 4 suppliers. Subscribe to see all 4, every one of the 823 deliveries recorded 2011–2023, mine-level origins, transport mode and the delivered price paid — plus sorting, filtering and Excel export.
946 MW across 2 generating units in service. A further 4 units are listed as standby, out of service, planned, retired or canceled.
Who owns and operates it?
Owned by Wec Energy Group Inc and Dairyland Power Cooperative and operated by Wisconsin Public Service Corp, filed as investor-owned utility. 2 owner stakes are filed on jointly held units.
Which grid does it sell into?
MISO (Midcontinent Independent Transmission System Operator, Inc.) is its balancing authority, inside NERC's ReliabilityFirst region.
How old is it?
The capacity-weighted average megawatt here came online in 1998. The oldest operating unit is Unit 3 (1981); the newest is Unit 4 (2008).
When is it due to retire?
No retirement date has been filed for any operating unit at Weston. An absent date means none is currently filed, not that the plant will run indefinitely.
What does it burn, and where does the fuel come from?
In 2023 it burned coal and natural gas. Coal delivered in 2023 came from 3 coal suppliers, from mines in Wyoming — principally North Antelope Rochelle Mine. Other fuels (natural gas) came from 1 supplier in 2023.
How much does it spend on fuel?
An estimated $81.7M in 2023 — coal $81.1M and natural gas $566,713. No agency publishes this site's whole fuel bill, so this is an AEA estimate rather than a reported figure.
How much CO₂ does it emit?
3.03 Mt in 2023, reported to the EPA — the 158th highest of 6,030 US facilities that reported. Down from 5.59 Mt in 2011.