CO₂ emitted571,225t2023 · reported to EPA · 870th highest of 6,030 in the US
Rank in California#20of 1,713 · by capacity · #489 (tied) of 13,147 US
Reported suppliers12023 · 12 deliveries
Capacity factor25%2023
Location
What it burns
2023 · reported
Share of reported fuel consumption
100% Natural gas · 10.8 TBtu · reported
CO₂ emitted, Mt · 2011–2023
Reported (through 2023)
Generating units
8 of 8 shown · 690 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit 8
264.4
Natural Gas
Natural Gas Fired Combined Cycle
2003
Operating
Unit 6
182.8
Natural Gas
Natural Gas Fired Combined Cycle
2003
Operating
Unit 7
182.8
Natural Gas
Natural Gas Fired Combined Cycle
2003
Operating
Unit 5
60.5
Natural Gas
Natural Gas Fired Combustion Turbine
2001
Operating
Unit 3
172.8
Natural Gas
Natural Gas Steam Turbine
1955
Retired 2003
Unit 4
172.8
Natural Gas
Natural Gas Steam Turbine
1956
Retired 2003
Unit 1
100.0
Natural Gas
Natural Gas Steam Turbine
1954
Retired 1992
Unit 2
100.0
Natural Gas
Natural Gas Steam Turbine
1954
Retired 1992
All 8 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; co-firing fuels and fuel-switching times; NOₓ, particulate and mercury controls with compliance years; cooling system and water source with withdrawal rate; stack height.
Figures are volumes delivered in 2023, not volumes burned. Tons are shown for coal only.
The supplier is shown. Subscribe to see every one of the 154 deliveries recorded 2011–2023, mine-level origins, transport mode and the delivered price paid — plus sorting, filtering and Excel export.
690 MW across 4 generating units in service. A further 4 units are listed as standby, out of service, planned, retired or canceled.
Who owns and operates it?
Owned by City of Los Angeles California (100%) and operated by Los Angeles Department of Water & Power, filed as municipally owned utility.
Which grid does it sell into?
LDWP (Los Angeles Department of Water and Power) is its balancing authority, inside NERC's WECC region.
How old is it?
The capacity-weighted average megawatt here came online in 2003. The oldest operating unit is Unit 5 (2001); the newest are Unit 8, Unit 6 and Unit 7 (2003).
When is it due to retire?
No retirement date has been filed for any operating unit at Valley Generating Station. An absent date means none is currently filed, not that the plant will run indefinitely.
What does it burn, and where does the fuel come from?
In 2023 it burned natural gas. Natural gas came from 1 supplier in 2023.
How much does it spend on fuel?
Its fuel receipts report a delivered cost of $86.5M in 2023.
How much CO₂ does it emit?
571,225 t in 2023, reported to the EPA — the 870th highest of 6,030 US facilities that reported. Up from 453,858 t in 2011.