Pasadena, Harris County, Texas · ERCOT · operated by Pasadena Cogeneration LP · owned by CPN Management LP
2023 · headline year
Fuel spend$96.1M2023 · estimate
Capacity in service815MW5 units · gas
Net generation4.67TWh2023 · reported
CO₂ emitted1.9Mt2023 · reported to EPA · 323rd highest of 6,030 in the US
Rank in Texas#48of 941 · by capacity · #392 of 13,147 US
Reported suppliers12023 · 12 deliveries
Capacity factor65%2023
Location
What it burns
2023 · reported
Share of reported fuel consumption
100% Natural gas · 35.6 TBtu · reported · $96.1M est.
CO₂ emitted, Mt · 2011–2023
Reported (through 2023)
Generating units
5 of 5 shown · 815 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit CTG2
185.0
Natural Gas
Natural Gas Fired Combined Cycle
2000
Operating
Unit CTG3
185.0
Natural Gas
Natural Gas Fired Combined Cycle
2000
Operating
Unit STG2
185.0
Natural Gas
Natural Gas Fired Combined Cycle
2000
Operating
Unit CTG1
175.0
Natural Gas
Natural Gas Fired Combined Cycle
1998
Operating
Unit STG1
85.0
Natural Gas
Natural Gas Fired Combined Cycle
1998
Operating
All 5 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; NOₓ, particulate and mercury controls with compliance years; cooling system and water source with withdrawal rate; stack height; ownership stakes where a unit is jointly held.
Figures are volumes delivered in 2023, not volumes burned. Tons are shown for coal only.
The supplier is shown. Subscribe to see every one of the 197 deliveries recorded 2011–2023, mine-level origins, transport mode and the delivered price paid — plus sorting, filtering and Excel export.
Kinder Morgan Tejas Pipeline LLC, Kinder Morgan Texas Pipeline LLC, Enterprise Texas Pipeline
EIA plant ID
55047
Common questions
How big is Pasadena Power Plant?
815 MW across 5 generating units in service.
Who owns and operates it?
Owned by CPN Management LP (100%) and operated by Pasadena Cogeneration LP, filed as independent power producer.
Which grid does it sell into?
ERCOT (Electric Reliability Council of Texas, Inc.) is its balancing authority, inside NERC's Texas RE region.
How old is it?
The capacity-weighted average megawatt here came online in 1999. The oldest operating units are Unit CTG1 and Unit STG1 (1998); the newest are Unit CTG2, Unit CTG3 and Unit STG2 (2000).
When is it due to retire?
No retirement date has been filed for any operating unit at Pasadena Power Plant. An absent date means none is currently filed, not that the plant will run indefinitely.
What does it burn, and where does the fuel come from?
In 2023 it burned natural gas. Natural gas came from 1 supplier in 2023.
How much does it spend on fuel?
An estimated $96.1M in 2023. No agency publishes this site's whole fuel bill, so this is an AEA estimate rather than a reported figure.
How much CO₂ does it emit?
1.9 Mt in 2023, reported to the EPA — the 323rd highest of 6,030 US facilities that reported. Up from 1.51 Mt in 2011.