Biron, Wood County, Wisconsin · MISO · operated by ND Paper, Inc. · owned by ND Paper LLC
2023 · headline year
Fuel spend$26.1M2023 · estimate
Capacity in service44.6MW3 units · gas + coal · 1 more on standby or out of service
Net generation186GWh2023 · reported
CO₂ emitted320,692t2023 · reported to EPA · 1,193rd highest of 6,030 in the US
Rank in Wisconsin#63of 258 · by capacity · #3,669 (tied) of 13,147 US
Reported suppliersNot reported2023 · last deliveries 2017
Location
What it burns
2023 · reported
Share of reported fuel consumption
61% Natural gas · 2.74 TBtu · reported · $17.9M est.39% Coal · 1.75 TBtu · reported · $8.19M est.
Natural gas supplies 61% of the fuel energy it burned in 2023. Per unit of heat, natural gas costs ND Paper Inc - Biron Division an estimated 1.4× more than coal — and natural gas is 2 of its 3 operating units and 52% of operating capacity.
CO₂ emitted, t · 2011–2023
Reported (through 2023)
Generating units
4 of 4 shown · 44.6 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit GEN5
21.5
Subbituminous
Conventional Steam Coal
1987
Operating
Unit GEN1
17.0
Bituminous coal
Conventional Steam Coal
1964
Out of service
Unit GEN4
15.6
Natural Gas
Natural Gas Steam Turbine
1957
Operating
Unit GEN3
7.5
Natural Gas
Natural Gas Steam Turbine
1947
Operating
All 4 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; co-firing fuels and fuel-switching times; NOₓ, particulate and mercury controls with compliance years.
44.6 MW across 3 generating units in service — 23.1 MW of natural gas and 21.5 MW of coal. A further 1 unit is listed as standby, out of service, planned, retired or canceled.
Who owns and operates it?
Owned by ND Paper LLC (100%) and operated by ND Paper, Inc., filed as independent power producer.
Which grid does it sell into?
MISO (Midcontinent Independent Transmission System Operator, Inc.) is its balancing authority, inside NERC's MRO region.
How old is it?
The capacity-weighted average megawatt here came online in 1970. The oldest operating unit is Unit GEN3 (1947); the newest is Unit GEN5 (1987).
When is it due to retire?
No retirement date has been filed for any operating unit at ND Paper Inc - Biron Division. An absent date means none is currently filed, not that the plant will run indefinitely.
What does it burn, and where does the fuel come from?
In 2023 it burned natural gas and coal.
How much does it spend on fuel?
An estimated $26.1M in 2023 — natural gas $17.9M and coal $8.19M. No agency publishes this site's whole fuel bill, so this is an AEA estimate rather than a reported figure.
How much CO₂ does it emit?
320,692 t in 2023, reported to the EPA — the 1,193rd highest of 6,030 US facilities that reported. Down from 472,469 t in 2011.