Natural gas supplies 77% of the fuel energy it burned in 2023.
CO₂ emitted, Mt · 2011–2023
Reported (through 2023)
Generating units
8 of 8 shown · 447 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit CT8
148.0
Natural Gas
Natural Gas Fired Combined Cycle
1992
Operating
Unit CT7
145.0
Natural Gas
Natural Gas Fired Combined Cycle
1990
Operating
Unit CW8
79.2
Natural Gas
Natural Gas Fired Combined Cycle
1992
Operating
Unit CW7
74.4
Natural Gas
Natural Gas Fired Combined Cycle
1990
Operating
Unit 6
693.9
Bituminous coal
Conventional Steam Coal
1969
Retired 2023
Unit 5
359.0
Bituminous coal
Conventional Steam Coal
1964
Retired 2023
Unit 4
187.5
Bituminous coal
Conventional Steam Coal
1960
Retired 2019
Unit 3
112.5
Bituminous coal
Conventional Steam Coal
1952
Retired 2019
All 8 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; co-firing fuels and fuel-switching times; SO₂ scrubber type, sorbent and removal efficiency; NOₓ, particulate and mercury controls with compliance years; cooling system and water source with withdrawal rate; stack height.
Figures are volumes delivered in 2023, not volumes burned. Tons are shown for coal only. Deliveries and consumption are reported separately and need not match in a year (stockpiles, and pipeline gas that fuel receipts do not capture).
Showing 1 of 3 suppliers. Subscribe to see all 3, every one of the 1,191 deliveries recorded 2011–2023, mine-level origins, transport mode and the delivered price paid — plus sorting, filtering and Excel export.
447 MW across 4 generating units in service. A further 4 units are listed as standby, out of service, planned, retired or canceled.
Who owns and operates it?
Owned by Dominion Energy Inc (100%) and operated by Virginia Electric & Power Co, filed as investor-owned utility.
Which grid does it sell into?
PJM (PJM Interconnection, LLC) is its balancing authority, inside NERC's SERC region.
How old is it?
The capacity-weighted average megawatt here came online in 1991. The oldest operating units are Unit CT7 and Unit CW7 (1990); the newest are Unit CT8 and Unit CW8 (1992).
When is it due to retire?
No retirement date has been filed for any operating unit at Chesterfield Power Station. An absent date means none is currently filed, not that the plant will run indefinitely.
What does it burn, and where does the fuel come from?
In 2023 it burned natural gas and coal. Coal delivered in 2023 came from 1 coal supplier, from mines in West Virginia — principally Loveridge #22. Other fuels (natural gas) came from 2 suppliers in 2023.
How much does it spend on fuel?
Its fuel receipts report a delivered cost of $55.2M in 2023.
How much CO₂ does it emit?
1.29 Mt in 2023, reported to the EPA — the 470th highest of 6,030 US facilities that reported. Down from 6.14 Mt in 2011.