Baldwin, Randolph County, Illinois · MISO · operated by Dynegy Midwest Generation Inc · owned by Vistra Corp
2023 · headline year
The 2nd-largest reported CO₂ emitter among facilities in Illinois — 6.08 Mt in 2023, 100% coal by fuel energy in 2023, first unit online in 1970.
Fuel spend$136M2023 · estimate
Capacity in service1,260MW2 units · coal
Net generation5.9TWh2023 · reported
CO₂ emitted6.08Mt2023 · reported to EPA · 45th highest of 6,030 in the US
Rank in Illinois#12of 433 · by capacity · #207 of 13,147 US
Reported suppliers12023 · 46 deliveries
Capacity factor53%2023
Location
What it burns
2023 · reported
Share of reported fuel consumption
100% Coal · 64.1 TBtu · reported · $134M est.
CO₂ emitted, Mt · 2011–2023
Reported (through 2023)
Generating units
3 of 3 shown · 1,260 MW in service
Unit
Capacity MW
Fuel
Technology
Online
Status
Unit 2
634.5
Subbituminous
Conventional Steam Coal
1973
Operating
Unit 1
625.1
Subbituminous
Conventional Steam Coal
1970
Operating
Unit 3
634.5
Refined coal
Conventional Steam Coal
1975
Retired 2020
All 3 units shown. Behind each one, AEA holds the full engineering record: boiler design and firing type, efficiency at full and half load, turndown ratio; SO₂ scrubber type, sorbent and removal efficiency; NOₓ, particulate and mercury controls with compliance years; cooling system and water source with withdrawal rate; stack height.
Figures are volumes delivered in 2023, not volumes burned. Tons are shown for coal only.
The supplier is shown. Subscribe to see every one of the 477 deliveries recorded 2011–2023, mine-level origins, transport mode and the delivered price paid — plus sorting, filtering and Excel export.
1,260 MW across 2 generating units in service. A further 1 unit is listed as standby, out of service, planned, retired or canceled.
Who owns and operates it?
Owned by Vistra Corp (100%) and operated by Dynegy Midwest Generation Inc, filed as independent power producer.
Which grid does it sell into?
MISO (Midcontinent Independent Transmission System Operator, Inc.) is its balancing authority, inside NERC's SERC region.
How old is it?
The capacity-weighted average megawatt here came online in 1972. The oldest operating unit is Unit 1 (1970); the newest is Unit 2 (1973).
When is it due to retire?
Planned retirement dates are filed for 2 of 2 operating units: Unit 1 (2027) and Unit 2 (2027).
What does it burn, and where does the fuel come from?
In 2023 it burned coal. Coal delivered in 2023 came from 1 coal supplier, from mines in Wyoming — principally Eagle Butte Mine.
How much does it spend on fuel?
An estimated $136M in 2023 — coal $134M and oil & petroleum $2.34M. No agency publishes this site's whole fuel bill, so this is an AEA estimate rather than a reported figure.
How much CO₂ does it emit?
6.08 Mt in 2023, reported to the EPA — the 45th highest of 6,030 US facilities that reported. Down from 12.8 Mt in 2011.